Tandir Orthopedic Implants Tandir Orthopedic Implants

Custom Patient Specific Implant Maxillofacial Repair and Fixation System

Customization: Available
Customized: Customized
Certification: ISO, CE

Product Description

Basic Specifications

Condition
New
Usage
Correct Deformities, Fracture Fixation
Using Site
Head
OEM
Accept
Application
Craniomaxillofacial Repair and Reconstruction
Material
Medical Grade Titanium / PEEK
Packing
Standard Export Packing
Specification
25x30x12cm
Capacity
50,000 pieces/Year

Product Description

PEEK Patient Specific Implant (PSI) for Craniomaxillofacial Repair and Fixation

PEEK Patient Specific Implant

PEEK (Polyether Ether Ketone) Patient Specific Implant provides an improved solution for patients with a cranio-maxillofacial defect. Our technology and craftsmanship produce a perfect match to the specific anatomical requirement in a custom implant.

PEEK can be designed and provided in single or multiple pieces with just-fit or over-lay concept as indicated above. Additionally, this patient specific implant can be reliably fixated using cranial fixation systems.

Key Features

Excellent Biocompatibility Non-cytotoxic, corrosion resistance, non-carcinogenic, non-conductive, and hydrolysis resistance. Good biological characteristics and histocompatibility. Capable to sustain repeated steam, ETO sterilization and Gamma irradiation.
Outstanding Bio-Mechanical Character Exceeding tensile strength to the native bone and provide better protection to the cerebrum. Comparable mechanical strength to the artificial bone and capable to distract the stress effectively when deformity occurs.
Better Imaging Compatibility Non-Magnetic and highly translucent to X-ray. CT/MRI imaging diagnosis without scattering or artifacts.
Perfect Contour Reconstruction Precisely match the natural contour and convenient to implant. CAD/CAM technology allows to restore the defect models and reconstruct the natural contour of the brain.

Frequently Asked Questions

What are the primary benefits of using PEEK for cranial implants?
PEEK offers excellent biocompatibility, is non-conductive, and has a mechanical strength comparable to natural bone, providing superior protection and comfort for the patient.
Will this implant interfere with future MRI or CT scans?
No. PEEK is non-magnetic and highly translucent to X-rays, allowing for clear CT and MRI imaging without the scattering or artifacts often caused by metal implants.
How is the "Patient Specific" part of the implant achieved?
We use advanced CAD/CAM technology to restore defect models and precisely match the natural anatomical contour of the individual patient's skull.
Is the PEEK material resistant to sterilization?
Yes, PEEK is highly stable and can withstand repeated steam sterilization, ETO sterilization, and Gamma irradiation without degrading.
What is the mechanical advantage of PEEK over other materials?
PEEK provides exceptional tensile strength that exceeds native bone, effectively distracting stress during deformities while remaining lightweight.
Can these implants be used for both repair and reconstruction?
Yes, they are specifically designed for both craniomaxillofacial repair and complex reconstructions to restore natural aesthetics and function.